SMC 3/8" NPT Auto Drain (self-Draining) water trap & Air Filter. Free & Fast Shipping in all 50 states in USA.
SMC
Brand 3/8" NPT Auto Drain (Self - Draining) Water Trap & Filter
with Push to Connect Fitting at bottom. SMC Auto Drain Water Trap & Filter P/N AF30-N03C-2Z-A
with off white color full metal bowl.
SMC
Auto Drain water trap & filter will not only save time and effort
where you have to keep draining water traps manually, plus this will
protect your most expensive Air Ride Suspension parts & components .
These water traps can be used with any valve block/manifold application
as well as in between compressors & Tank setup. These are ideal for
any Air Lift 3P OR 3H kits where these can be used in between air tank
& valve manifold.
Product Details :
Product Brand - SMC
Manufacturer Part Number - AF30-N03C-2Z-A
Product Type- Water separation & particle filtration
Product Specifications:
Product Dimensions : 6.70" L X 2.0" W (From inlet to outlet side) 171MM Long X 50MM Wide
Max. Pressure Range - 150 PSI For Industrial applications with Maximum pressure capacity of 220 PSI ***Proof Pressure**
Thread Size & Type - 3/8" NPT
Filter Size - 5 Micron
Material : All metal construction (Off White Color Aluminum Bowl)
Country of origin - Made in China
Parts Included - (1) Auto Drain Water Trap with 5 FT 3/8" OD Airline/Tubiing
Product Features:
- Keep water and moisture out of your tank and air lines
- Made from industrial grade material for superior durability
- Designed to meet and exceed quality standards
- Performance part for perfect fit and function
- Easy to install
- Perfect fit for Viair 3/8" NPT Leader Hose Compressors as well as for Air Lift 3P & 3H self - leveling kits
Note:
Make Sure water trap is installed with air inlet & outlet arrows
in proper direction. Simply Screw the push to connect fitting at bottom
knob & then connect airline. These can be mounted away, higher
than air tank with Air Lift 3P & 3H kits.
Auto Drain Water Trap Working/Functionality:
When
pressure inside the bowl is released:
Even when
pressure inside the bowl (1) is released, spring (6) keeps piston (7) in its
upward position. This keeps the seal created by the seal (10) in place; thus,
the inside of the bowl (1) is shut off from the outside air. Therefore, even if
there is an accumulation of condensate in the bowl (1), it will not drain out.
When
pressure is applied inside the bowl:
Even when
pressure is applied inside the bowl (1), the combined force of spring (6) and
the pressure inside the bowl (1) keeps piston (7) in its upward position. This
maintains the seal created by the seal (10) in place; thus, the inside of the
bowl (1) is shut off from the outside air. If there is no accumulation of
condensate in the bowl (1) at this time float (2) will be pulled down by its
own weight, causing valve (4), which is connected to lever (3), to seal valve
seat (5).
When
there is an accumulation of condensate in the bowl:
Float (2)
rises due to its own buoyancy and pushes open the seal created by the valve
seat (5). Pressure passes from the bowl (1) to chamber (8). The result is that
the pressure inside chamber (8) surpasses the force of the spring (6) and
pushes piston (7) downwards. This causes the sealing action of seal (10) to be
interrupted and the accumulated condensate in the bowl (1) drains out through
the drain cock (11). Turning drain cock (11) manually counterclockwise lowers
piston (7), which pushes open the seal created by seal (10), thus allowing the
condensate to drain out
WARNING: This product can expose you to chemicals
including lead, which is known to the State of California to cause
cancer and birth defects or other reproductive harm. For more
information, go to www.P65Warnings.ca.gov.